Windows-Server-2003/tools/symcatupd.cmd

115 lines
2.5 KiB
Batchfile
Raw Permalink Normal View History

2024-08-04 01:28:15 +02:00
@echo off
setlocal ENABLEDELAYEDEXPANSION
if DEFINED _echo echo on
if DEFINED verbose echo on
REM ******************************************************************
REM
REM This script updates symbols.cat when the build lab takes backprops
REM for symbol files that are in symbols.cab
REM
REM ******************************************************************
if "%1" == "" goto Usage
REM Check the command line for /? -? or ?
for %%a in (./ .- .) do if ".%1." == "%%a?." goto Usage
if "%2" == "" (
set lang=usa
set mybinaries=%_NTTREE%
) else (
set lang=%2
set mybinaries=%relbins%\%2
)
REM
REM Decide which build we are working on
REM debug vs. retail and i386 vs. amd64 vs. ia64
REM
set SUBDIR=
if /i "%_BuildArch%" == "x86" (
if /i "%lang%" == "NEC_98" (
set SUBDIR=NEC98
) else (
set SUBDIR=i386
)
)
if /i "%_BuildArch%" == "ia64" (
set SUBDIR=ia64
)
if /i "%_BuildArch%" == "amd64" (
set SUBDIR=amd64
)
if "%SUBDIR%" == "" (
call errmsg "Environment variables PROCESSOR_ARCHITECTURE is not recognized"
goto errend
)
if /i "%_BuildType%" == "chk" (
set FRECHK=Debug
) else (
set FRECHK=Retail
)
set catalog=%mybinaries%\symbolcd\cd\symbols\%SUBDIR%\%FRECHK%\symbols.cat
set temp.txt=%mybinaries%\symbolcd\%lang%\update.txt
REM
REM Find out which symbol files, if any need to be updated in
REM the catalog file
REM
findstr /il %1 %mybinaries%\symbolcd\%lang%\symbolcd.txt > %temp.txt%
set Resign=FALSE
for /F "tokens=3 delims=," %%a in (%temp.txt%) do (
updcat %catalog% -a %mybinaries%\%%a
set Resign=TRUE
)
if /i "%Resign%" == "TRUE" (
echo %catalog% needs to be signed and propped
goto end
) else (
del %temp.txt%
echo No changes were made to %catalog%
goto errend
)
goto end
:Usage
echo.
echo Usage: symcatupd ^<file^> [^<language^>]
echo.
echo file The binary that is being updated.
echo associated lists and infs
echo cabs Update the out of date cabs
echo.
echo language Language must be one of the languages in codes.txt.
echo If language is not given on the command line,
echo usa is the default.
echo.
goto errend
:errend
endlocal
REM Set errorlevel to 1 in case of errors during execution.
REM Used by the build rule script "symbols.cmd" after calling "symbolcd.cmd".
seterror.exe 1
goto :EOF
:end
endlocal
REM Set errorlevel to 0 when the script finishes successfully.
REM Used by the build rule script "symbols.cmd" after calling "symbolcd.cmd".
seterror.exe 0