Windows-Server-2003/net/snmp/subagent/hostmib/hrswpren.c

457 lines
14 KiB
C
Raw Normal View History

2024-08-04 01:28:15 +02:00
/*
* HrSWRunPerfEntry.c v0.10
* Generated in conjunction with Management Factory scripts:
* script version: SNMPv1, 0.16, Apr 25, 1996
* project: D:\TEMP\EXAMPLE\HOSTMIB
****************************************************************************
* *
* (C) Copyright 1995 DIGITAL EQUIPMENT CORPORATION *
* *
* This software is an unpublished work protected under the *
* the copyright laws of the United States of America, all *
* rights reserved. *
* *
* In the event this software is licensed for use by the United *
* States Government, all use, duplication or disclosure by the *
* United States Government is subject to restrictions as set *
* forth in either subparagraph (c)(1)(ii) of the Rights in *
* Technical Data And Computer Software Clause at DFARS *
* 252.227-7013, or the Commercial Computer Software Restricted *
* Rights Clause at FAR 52.221-19, whichever is applicable. *
* *
****************************************************************************
*
* Facility:
*
* Windows NT SNMP Extension Agent
*
* Abstract:
*
* This module contains the code for dealing with the get, set, and
* instance name routines for the HrSWRunPerfEntry. Actual instrumentation code is
* supplied by the developer.
*
* Functions:
*
* A get and set routine for each attribute in the class.
*
* The routines for instances within the class.
*
* Author:
*
* D. D. Burns @ Webenable Inc
*
* Revision History:
*
* V1.00 - 05/14/97 D. D. Burns Genned: Thu Nov 07 16:48:05 1996
*
*/
#include <windows.h>
#include <malloc.h>
#include <snmp.h>
#include "mib.h"
#include "smint.h"
#include "hostmsmi.h"
#include "user.h" /* Developer supplied include file */
#include "HMCACHE.H" /* Cache-related definitions */
/*
| NOTE:
| The cache used by this table is the same one created for hrSWRun. The
| CACHEHEAD structure for it is located in "HRSWRUNE.C".
*/
/*
* GetHrSWRunPerfCPU
* The number of centi-seconds of the total system's CPU resources consumed
* by this process. Note that on a multi-processor syste
*
* Gets the value for HrSWRunPerfCPU.
*
* Arguments:
*
* outvalue address to return variable value
* accesss Reserved for future security use
* instance address of instance name as ordered native
* data type(s)
*
* Return Codes:
*
* Standard PDU error codes.
*
* SNMP_ERRORSTATUS_NOERROR Successful get
* SNMP_ERRORSTATUS_GENERR Catch-all failure code
* mibtget.c v0.10
*
| =============== From WebEnable Design Spec Rev 3 04/11/97==================
| hrSWRunPerfCPU
|
| ACCESS SYNTAX
| read-only INTEGER
|
| "The number of centi-seconds of the total system's CPU resources consumed by
| this process. Note that on a multi-processor system, this value may increment
| by more than one centi-second in one centi-second of real (wall clock) time."
|
| DISCUSSION:
|
| <POA-22> Given the performance monitoring counters available in the Registry,
| how do we compute this SNMP attribute value for a given process?
|
| RESOLVED >>>>>>>>
| <POA-22> I think we should just use the PerfMon code for this.
| RESOLVED >>>>>>>>
|
|============================================================================
| 1.3.6.1.2.1.25.5.1.1.1.<instance>
| | | | |
| | | | *-hrSWRunPerfCPU
| | | *-hrSWRunPerfEntry
| | *-hrSWRunPerfTable
| *-hrSWRunPerf
*/
UINT
GetHrSWRunPerfCPU(
OUT Integer *outvalue ,
IN Access_Credential *access ,
IN InstanceName *instance )
{
ULONG index; /* As fetched from instance structure */
CACHEROW *row; /* Row entry fetched from cache */
/*
| Grab the instance information
*/
index = GET_INSTANCE(0);
/*
| Use it to find the right entry in the cache
*/
if ((row = FindTableRow(index, &hrSWRunTable_cache)) == NULL) {
return SNMP_ERRORSTATUS_GENERR;
}
*outvalue = row->attrib_list[HRSP_CPU].u.number_value;
return SNMP_ERRORSTATUS_NOERROR ;
} /* end of GetHrSWRunPerfCPU() */
/*
* GetHrSWRunPerfMem
* The total amount of real system memory allocated to this process.
*
* Gets the value for HrSWRunPerfMem.
*
* Arguments:
*
* outvalue address to return variable value
* accesss Reserved for future security use
* instance address of instance name as ordered native
* data type(s)
*
* Return Codes:
*
* Standard PDU error codes.
*
* SNMP_ERRORSTATUS_NOERROR Successful get
* SNMP_ERRORSTATUS_GENERR Catch-all failure code
* mibtget.c v0.10
*
| =============== From WebEnable Design Spec Rev 3 04/11/97==================
| hrSWRunPerfMem
|
| ACCESS SYNTAX
| read-only KBytes
|
| "The total amount of real system memory allocated to this process."
|
| DISCUSSION:
|
| <POA-23> Given the performance monitoring counters available in the Registry,
| how do we compute this SNMP attribute value for a given process?
|
| RESOLVED >>>>>>>>
| <POA-22> I think we should just use the PerfMon code for this.
| RESOLVED >>>>>>>>
|
|============================================================================
| 1.3.6.1.2.1.25.5.1.1.2.<instance>
| | | | |
| | | | *-hrSWRunPerfMem
| | | *-hrSWRunPerfEntry
| | *-hrSWRunPerfTable
| *-hrSWRunPerf
*/
UINT
GetHrSWRunPerfMem(
OUT KBytes *outvalue ,
IN Access_Credential *access ,
IN InstanceName *instance )
{
ULONG index; /* As fetched from instance structure */
CACHEROW *row; /* Row entry fetched from cache */
/*
| Grab the instance information
*/
index = GET_INSTANCE(0);
/*
| Use it to find the right entry in the cache
*/
if ((row = FindTableRow(index, &hrSWRunTable_cache)) == NULL) {
return SNMP_ERRORSTATUS_GENERR;
}
*outvalue = row->attrib_list[HRSP_MEM].u.number_value;
return SNMP_ERRORSTATUS_NOERROR ;
} /* end of GetHrSWRunPerfMem() */
/*
* HrSWRunPerfEntryFindInstance
*
* This routine is used to verify that the specified instance is
* valid.
*
* Arguments:
*
* FullOid Address for the full oid - group, variable,
* and instance information
* instance Address for instance specification as an oid
*
* Return Codes:
*
* SNMP_ERRORSTATUS_NOERROR Instance found and valid
* SNMP_ERRORSTATUS_NOSUCHNAME Invalid instance
*
*/
UINT
HrSWRunPerfEntryFindInstance( IN ObjectIdentifier *FullOid ,
IN OUT ObjectIdentifier *instance )
{
UINT tmp_instance ;
//
// Developer instrumentation code to find appropriate instance goes here.
// For non-tables, it is not necessary to modify this routine. However, if
// there is any context that needs to be set, it can be done here.
//
if ( FullOid->idLength <= HRSWRUNPERFENTRY_VAR_INDEX )
// No instance was specified
return SNMP_ERRORSTATUS_NOSUCHNAME ;
else if ( FullOid->idLength != HRSWRUNPERFENTRY_VAR_INDEX + 1 )
// Instance length is more than 1
return SNMP_ERRORSTATUS_NOSUCHNAME ;
else
// The only valid instance for a non-table are instance 0. If this
// is a non-table, the following code validates the instances. If this
// is a table, developer modification is necessary below.
tmp_instance = FullOid->ids[ HRSWRUNPERFENTRY_VAR_INDEX ] ;
/*
| Check for age-out and possibly refresh the entire cache for the
| hrSWRun(Perf) table before we check to see if the instance is there.
*/
if (hrSWRunCache_Refresh() == FALSE) {
return SNMP_ERRORSTATUS_GENERR;
}
/*
| For hrSWRunPerf, the instance arc(s) is a single arc, and it must
| correctly select an entry in the hrSWRun(Perf) Table cache.
| Check that here.
*/
if ( FindTableRow(tmp_instance, &hrSWRunTable_cache) == NULL ) {
return SNMP_ERRORSTATUS_NOSUCHNAME ;
}
else
{
// the instance is valid. Create the instance portion of the OID
// to be returned from this call.
instance->ids[ 0 ] = tmp_instance ;
instance->idLength = 1 ;
}
return SNMP_ERRORSTATUS_NOERROR ;
} /* end of HrSWRunPerfEntryFindInstance() */
/*
* HrSWRunPerfEntryFindNextInstance
*
* This routine is called to get the next instance. If no instance
* was passed than return the first instance (1).
*
* Arguments:
*
* FullOid Address for the full oid - group, variable,
* and instance information
* instance Address for instance specification as an oid
*
* Return Codes:
*
* SNMP_ERRORSTATUS_NOERROR Instance found and valid
* SNMP_ERRORSTATUS_NOSUCHNAME Invalid instance
*
*/
UINT
HrSWRunPerfEntryFindNextInstance( IN ObjectIdentifier *FullOid ,
IN OUT ObjectIdentifier *instance )
{
//
// Developer supplied code to find the next instance of class goes here.
// If this is a class with cardinality 1, no modification of this routine
// is necessary unless additional context needs to be set.
// If the FullOid does not specify an instance, then the only instance
// of the class is returned. If this is a table, the first row of the
// table is returned.
//
// If an instance is specified and this is a non-table class, then NOSUCHNAME
// is returned so that correct MIB rollover processing occurs. If this is
// a table, then the next instance is the one following the current instance.
// If there are no more instances in the table, return NOSUCHNAME.
//
CACHEROW *row;
ULONG tmp_instance;
if ( FullOid->idLength <= HRSWRUNPERFENTRY_VAR_INDEX )
{
/*
| Too short: must return the instance arc that selects the first
| entry in the table if there is one.
*/
tmp_instance = 0;
}
else {
/*
| There is at least one instance arc. Even if it is the only arc
| we use it as the "index" in a request for the "NEXT" one.
*/
tmp_instance = FullOid->ids[ HRSWRUNPERFENTRY_VAR_INDEX ] ;
}
/*
| Check for age-out and possibly refresh the entire cache for the
| hrSWRun(Perf) table before we check to see if the instance is there.
*/
if (hrSWRunCache_Refresh() == FALSE) {
return SNMP_ERRORSTATUS_GENERR;
}
/* Now go off and try to find the next instance in the table */
if ((row = FindNextTableRow(tmp_instance, &hrSWRunTable_cache)) == NULL) {
return SNMP_ERRORSTATUS_NOSUCHNAME ;
}
instance->ids[ 0 ] = row->index ;
instance->idLength = 1 ;
return SNMP_ERRORSTATUS_NOERROR ;
} /* end of HrSWRunPerfEntryFindNextInstance() */
/*
* HrSWRunPerfEntryConvertInstance
*
* This routine is used to convert the object id specification of an
* instance into an ordered native representation. The object id format
* is that object identifier that is returned from the Find Instance
* or Find Next Instance routines. It is NOT the full object identifier
* that contains the group and variable object ids as well. The native
* representation is an argc/argv-like structure that contains the
* ordered variables that define the instance. This is specified by
* the MIB's INDEX clause. See RFC 1212 for information about the INDEX
* clause.
*
*
* Arguments:
*
* oid_spec Address of the object id instance specification
* native_spec Address to return the ordered native instance
* specification
*
* Return Codes:
*
* SUCCESS Conversion complete successfully
* FAILURE Unable to convert object id into native format
*
*/
UINT
HrSWRunPerfEntryConvertInstance( IN ObjectIdentifier *oid_spec ,
IN OUT InstanceName *native_spec )
{
static char *array; /* The address of this (char *) is passed back */
/* as though it were an array of length 1 of these */
/* types. */
static ULONG inst; /* The address of this ULONG is passed back */
/* (Obviously, no "free()" action is needed) */
/* We only expect the one arc in "oid_spec" */
inst = oid_spec->ids[0];
array = (char *) &inst;
native_spec->count = 1;
native_spec->array = &array;
return SUCCESS ;
} /* end of HrSWRunPerfEntryConvertInstance() */
/*
* HrSWRunPerfEntryFreeInstance
*
* This routine is used to free an ordered native representation of an
* instance name.
*
* Arguments:
*
* instance Address to return the ordered native instance
* specification
*
* Return Codes:
*
*
*/
void
HrSWRunPerfEntryFreeInstance( IN OUT InstanceName *instance )
{
//
// Developer supplied code to free native representation of instance name goes here.
//
} /* end of HrSWRunPerfEntryFreeInstance() */