436 lines
16 KiB
Batchfile
436 lines
16 KiB
Batchfile
@REM -----------------------------------------------------------------
|
|
@REM
|
|
@REM migwiz.cmd - JThaler, CalinN
|
|
@REM This will call iexpress to generate a self-extracting CAB that
|
|
@REM will be used when running our tool off the installation CD's
|
|
@REM tools menu.
|
|
@REM This also copies shfolder.dll into valueadd/msft/usmt
|
|
@REM for use in our command line distribution
|
|
@REM
|
|
@REM Copyright (c) Microsoft Corporation. All rights reserved.
|
|
@REM
|
|
@REM -----------------------------------------------------------------
|
|
@if NOT defined HOST_PROCESSOR_ARCHITECTURE set HOST_PROCESSOR_ARCHITECTURE=%PROCESSOR_ARCHITECTURE%
|
|
@if defined _CPCMAGIC goto CPCBegin
|
|
@perl -x "%~f0" %*
|
|
@goto :EOF
|
|
#!perl
|
|
use strict;
|
|
use lib $ENV{RAZZLETOOLPATH} . "\\PostBuildScripts";
|
|
use lib $ENV{RAZZLETOOLPATH};
|
|
use PbuildEnv;
|
|
use ParseArgs;
|
|
|
|
sub Usage { print<<USAGE; exit(1) }
|
|
migwiz.cmd [-l <language>]
|
|
|
|
This is for the Files and Settings Transfer Wizard (aka Migration
|
|
Wizard, or migwiz). It runs iexpress to generate a self-extracting
|
|
CAB and install into support\tools.
|
|
This will also copy shfolder.dll into valueadd\\msft\\usmt for
|
|
distribution with the command line tool.
|
|
USAGE
|
|
|
|
parseargs('?' => \&Usage);
|
|
|
|
|
|
# *** NEXT FEW LINES ARE TEMPLATE ***
|
|
$ENV{"_CPCMAGIC"}++;exit(system($0)>>8);
|
|
__END__
|
|
:CPCBegin
|
|
set _CPCMAGIC=
|
|
setlocal ENABLEDELAYEDEXPANSION ENABLEEXTENSIONS
|
|
REM *** BEGIN YOUR CMD SCRIPT BELOW ***
|
|
|
|
REM
|
|
REM x86 only!
|
|
REM
|
|
|
|
if not defined x86 goto end
|
|
|
|
|
|
|
|
REM temporarily create the migwiz.exe.manifest file
|
|
|
|
if exist %_NTPostBld%\migwiz.man (
|
|
call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migwiz.man %_NTPostBld%\migwiz.exe.manifest"
|
|
)
|
|
|
|
set migpath=
|
|
|
|
@REM
|
|
@REM if the EXE already exists, we are probably in SP tree case,
|
|
@REM where not all the files are available. We are going to need
|
|
@REM to extract the files from the EXE and work from there.
|
|
@REM
|
|
if exist %_NTPostBld%\support\tools\fastwiz.exe goto SPScript
|
|
|
|
set WorkingDir=%_NTPostBld%
|
|
set SEDPath=%_NTPostBld%
|
|
|
|
:common
|
|
|
|
REM
|
|
REM Use iexpress.exe to generate the self-extracting executable;
|
|
REM
|
|
|
|
set doubledpath=%WorkingDir:\=\\%
|
|
|
|
REM
|
|
REM build the CAB that is placed inside the exe
|
|
REM
|
|
|
|
REM first update the sed file with the proper binaries directory
|
|
set migcab.sed=%temp%\migcab.sed
|
|
perl -n -e "s/BINARIES_DIR/%doubledpath%/g;print $_;" < %SEDPath%\migcab.sed > %migcab.sed%
|
|
|
|
REM Validate that the sed file exists
|
|
if not exist %migcab.sed% (
|
|
call errmsg.cmd "File %migcab.sed% not found."
|
|
popd& goto end
|
|
)
|
|
|
|
REM Cleanup leftover CAB file if there
|
|
if exist %WorkingDir%\migwiz.cab del /f %WorkingDir%\migwiz.cab
|
|
|
|
REM
|
|
REM Munge the path so we use the correct iexpress.exe to build the package with...
|
|
REM NOTE: We *want* to use the one we just built (and for Intl localized)!
|
|
REM
|
|
set _NEW_PATH_TO_PREPEND=%RazzleToolPath%\%HOST_PROCESSOR_ARCHITECTURE%\loc\%LANG%
|
|
set _OLD_PATH_BEFORE_PREPENDING=%PATH%
|
|
set PATH=%_NEW_PATH_TO_PREPEND%;%PATH%
|
|
|
|
REM call iexpress on the new sed
|
|
call ExecuteCmd.cmd "start /min /wait iexpress.exe /M /N /Q %migcab.sed%"
|
|
|
|
REM
|
|
REM Return the path to what it was before...
|
|
REM
|
|
set PATH=%_OLD_PATH_BEFORE_PREPENDING%
|
|
|
|
REM Validate that the CAB file exists
|
|
if not exist %WorkingDir%\migwiz.cab (
|
|
call errmsg.cmd "IExpress.exe failed on %migcab.sed%."
|
|
popd& goto end
|
|
)
|
|
|
|
REM Delete the temporary sed file
|
|
if exist %migcab.sed% del /f %migcab.sed%
|
|
|
|
REM
|
|
REM Now build the self-extracting EXE
|
|
REM
|
|
|
|
REM first update the sed file with the proper binaries directory
|
|
set migwiz.sed=%temp%\migwiz.sed
|
|
perl -n -e "s/BINARIES_DIR/%doubledpath%/g;print $_;" < %SEDPath%\migwiz.sed > %migwiz.sed%
|
|
|
|
REM Validate that the sed file exists
|
|
if not exist %migwiz.sed% (
|
|
call errmsg.cmd "File %migwiz.sed% not found."
|
|
popd& goto end
|
|
)
|
|
|
|
REM Cleanup leftover EXE file if there
|
|
set outpath=%WorkingDir%\support\tools
|
|
if exist %outpath%\fastwiz.exe del /f %outpath%\fastwiz.exe
|
|
|
|
REM
|
|
REM Munge the path so we use the correct iexpress.exe to build the package with...
|
|
REM NOTE: We *want* to use the one we just built (and for Intl localized)!
|
|
REM
|
|
set _NEW_PATH_TO_PREPEND=%RazzleToolPath%\%HOST_PROCESSOR_ARCHITECTURE%\loc\%LANG%
|
|
set _OLD_PATH_BEFORE_PREPENDING=%PATH%
|
|
set PATH=%_NEW_PATH_TO_PREPEND%;%PATH%
|
|
|
|
REM call iexpress on the new sed
|
|
call ExecuteCmd.cmd "start /min /wait iexpress.exe /M /N /Q %migwiz.sed%"
|
|
|
|
REM
|
|
REM Return the path to what it was before...
|
|
REM
|
|
set PATH=%_OLD_PATH_BEFORE_PREPENDING%
|
|
|
|
REM Validate that the EXE file exists
|
|
if not exist %outpath%\fastwiz.exe (
|
|
call errmsg.cmd "IExpress.exe failed on %migwiz.sed%."
|
|
popd& goto end
|
|
)
|
|
popd
|
|
|
|
REM Delete the temporary sed file
|
|
if exist %migwiz.sed% del /f %migwiz.sed%
|
|
|
|
REM Cleanup CAB file used to create the EXE
|
|
if exist %WorkingDir%\migwiz.cab del /f %WorkingDir%\migwiz.cab
|
|
|
|
|
|
|
|
|
|
REM
|
|
REM Now copy shfolder.dll into the loadstate/scanstate distribution
|
|
REM
|
|
|
|
set shfolder.dll=%_NTPostBld%\shfolder.dll
|
|
|
|
if not exist %shfolder.dll% (
|
|
if not defined migpath (
|
|
call errmsg.cmd "File %shfolder.dll% not found."
|
|
goto end
|
|
)
|
|
) else (
|
|
if exist %_NTPostBld%\valueadd\msft\usmt\shfolder.dll del /f %_NTPostBld%\valueadd\msft\usmt\shfolder.dll
|
|
call ExecuteCmd.cmd "xcopy /fd /Y %shfolder.dll% %_NTPostBld%\valueadd\msft\usmt\"
|
|
)
|
|
|
|
|
|
|
|
|
|
|
|
REM
|
|
REM create the ansi subdirectory inside valueadd\msft\usmt
|
|
REM
|
|
|
|
set valueadd=%_NTPostBld%\valueadd\msft\usmt
|
|
set ansidir=%valueadd%\ansi
|
|
|
|
if exist %ansidir% rd /q /s %ansidir%
|
|
call ExecuteCmd.cmd "md %ansidir%"
|
|
call ExecuteCmd.cmd "xcopy /fd /i /Y %valueadd%\*.inf %ansidir%"
|
|
if exist %valueadd%\iconlib.dll call ExecuteCmd.cmd "xcopy /fd /i /Y %valueadd%\iconlib.dll %ansidir%"
|
|
if exist %valueadd%\log.dll call ExecuteCmd.cmd "xcopy /fd /i /Y %valueadd%\log.dll %ansidir%"
|
|
if exist %valueadd%\shfolder.dllcall ExecuteCmd.cmd "xcopy /fd /i /Y %valueadd%\shfolder.dll %ansidir%"
|
|
|
|
REM
|
|
REM Hey guess what? I can't MOVE stuff, or it'll break PopulateFromVBL
|
|
REM Either binplace to the final destination or use [x]copy
|
|
REM
|
|
if exist %valueadd%\scanstate_a.exe call ExecuteCmd.cmd "copy /Y %valueadd%\scanstate_a.exe %ansidir%\scanstate.exe"
|
|
if exist %valueadd%\migism_a.dll call ExecuteCmd.cmd "copy /Y %valueadd%\migism_a.dll %ansidir%\migism.dll"
|
|
if exist %valueadd%\script_a.dll call ExecuteCmd.cmd "copy /Y %valueadd%\script_a.dll %ansidir%\script.dll"
|
|
if exist %valueadd%\sysmod_a.dll call ExecuteCmd.cmd "copy /Y %valueadd%\sysmod_a.dll %ansidir%\sysmod.dll"
|
|
if exist %valueadd%\unctrn_a.dll call ExecuteCmd.cmd "copy /Y %valueadd%\unctrn_a.dll %ansidir%\unctrn.dll"
|
|
|
|
goto end
|
|
|
|
|
|
|
|
REM
|
|
REM if the EXE already exists, we are probably in SP tree case,
|
|
REM where not all the files are available. We are going to need
|
|
REM to extract the files from the EXE and work from there.
|
|
REM
|
|
:SPScript
|
|
|
|
REM Let's build two directories in the %temp%
|
|
set migpath=%temp%\migpath
|
|
|
|
REM Delete the migpath directory if it's there
|
|
if exist %migpath% (
|
|
call ExecuteCmd.cmd "rd /s /q %migpath%"
|
|
)
|
|
|
|
REM Create a new migpath directory
|
|
call ExecuteCmd.cmd "md %migpath%"
|
|
|
|
REM Verify that it's there
|
|
if not exist %migpath% (
|
|
call errmsg.cmd "Can't create directory %migpath%"
|
|
goto end
|
|
)
|
|
|
|
REM Now extract all the files from the EXE in the migpath temporary directory
|
|
call ExecuteCmd.cmd "start /min /wait %_NTPostBld%\support\tools\fastwiz.exe /Q /T:%migpath% /C"
|
|
|
|
REM Now extract all the files from the CAB in the temporary directory
|
|
REM
|
|
REM Munge the path so we use the correct extract.exe to build the package with...
|
|
REM NOTE: We *want* to use the one we just built (and for Intl localized)!
|
|
REM
|
|
set _NEW_PATH_TO_PREPEND=%RazzleToolPath%\%HOST_PROCESSOR_ARCHITECTURE%\loc\%LANG%
|
|
set _OLD_PATH_BEFORE_PREPENDING=%PATH%
|
|
set PATH=%_NEW_PATH_TO_PREPEND%;%PATH%
|
|
|
|
REM call extract.exe
|
|
call ExecuteCmd.cmd "start /min /wait extract.exe /L %migpath% %migpath%\migwiz.cab *.*"
|
|
|
|
REM
|
|
REM Return the path to what it was before...
|
|
REM
|
|
set PATH=%_OLD_PATH_BEFORE_PREPENDING%
|
|
|
|
REM Now let's copy all the files that we have here on top of the extracted ones
|
|
if exist %_NTPostBld%\usmtdef.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\usmtdef.inf %migpath%"
|
|
if exist %_NTPostBld%\guitrn.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\guitrn.dll %migpath%"
|
|
if exist %_NTPostBld%\guitrn_a.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\guitrn_a.dll %migpath%"
|
|
if exist %_NTPostBld%\iconlib.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\iconlib.dll %migpath%"
|
|
if exist %_NTPostBld%\log.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\log.dll %migpath%"
|
|
if exist %_NTPostBld%\migapp.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migapp.inf %migpath%"
|
|
if exist %_NTPostBld%\migism.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migism.dll %migpath%"
|
|
if exist %_NTPostBld%\migism.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migism.inf %migpath%"
|
|
if exist %_NTPostBld%\migism_a.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migism_a.dll %migpath%"
|
|
if exist %_NTPostBld%\migsys.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migsys.inf %migpath%"
|
|
if exist %_NTPostBld%\miguser.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\miguser.inf %migpath%"
|
|
if exist %_NTPostBld%\migwiz.exe call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migwiz.exe %migpath%"
|
|
if exist %_NTPostBld%\migwiz.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migwiz.inf %migpath%"
|
|
if exist %_NTPostBld%\migwiz_a.exe call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migwiz_a.exe %migpath%"
|
|
if exist %_NTPostBld%\script.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\script.dll %migpath%"
|
|
if exist %_NTPostBld%\script_a.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\script_a.dll %migpath%"
|
|
if exist %_NTPostBld%\shfolder.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\shfolder.dll %migpath%"
|
|
if exist %_NTPostBld%\sysfiles.inf call ExecuteCmd.cmd "copy /Y %_NTPostBld%\sysfiles.inf %migpath%"
|
|
if exist %_NTPostBld%\sysmod.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\sysmod.dll %migpath%"
|
|
if exist %_NTPostBld%\sysmod_a.dll call ExecuteCmd.cmd "copy /Y %_NTPostBld%\sysmod_a.dll %migpath%"
|
|
if exist %_NTPostBld%\migwiz.exe.manifest call ExecuteCmd.cmd "copy /Y %_NTPostBld%\migwiz.exe.manifest %migpath%"
|
|
|
|
REM Next step. Let's recreate the CAB and the EXE files
|
|
REM For this we are going to set the WorkingDir and go to the common label.
|
|
|
|
set WorkingDir=%migpath%
|
|
|
|
REM Also, we need to make sure that the SED files exist. If not, we are going to create them
|
|
|
|
if exist %_NTPostBld%\migwiz.sed (
|
|
if exist %_NTPostBld%\migcab.sed (
|
|
set SEDPath=%_NTPostBld%
|
|
goto common
|
|
)
|
|
)
|
|
|
|
REM Yep, we must build them
|
|
|
|
REM build migcab.sed
|
|
ECHO [Version] 1>%migpath%\migcab.sed
|
|
ECHO Class=IEXPRESS 1>>%migpath%\migcab.sed
|
|
ECHO SEDVersion=3 1>>%migpath%\migcab.sed
|
|
ECHO [Options] 1>>%migpath%\migcab.sed
|
|
ECHO PackagePurpose=CreateCAB 1>>%migpath%\migcab.sed
|
|
ECHO ShowInstallProgramWindow=0 1>>%migpath%\migcab.sed
|
|
ECHO HideExtractAnimation=0 1>>%migpath%\migcab.sed
|
|
ECHO UseLongFileName=1 1>>%migpath%\migcab.sed
|
|
ECHO InsideCompressed=0 1>>%migpath%\migcab.sed
|
|
ECHO CAB_FixedSize=0 1>>%migpath%\migcab.sed
|
|
ECHO CAB_ResvCodeSigning=0 1>>%migpath%\migcab.sed
|
|
ECHO RebootMode=I 1>>%migpath%\migcab.sed
|
|
ECHO InstallPrompt=%%InstallPrompt%% 1>>%migpath%\migcab.sed
|
|
ECHO DisplayLicense=%%DisplayLicense%% 1>>%migpath%\migcab.sed
|
|
ECHO FinishMessage=%%FinishMessage%% 1>>%migpath%\migcab.sed
|
|
ECHO TargetName=%%TargetName%% 1>>%migpath%\migcab.sed
|
|
ECHO FriendlyName=%%FriendlyName%% 1>>%migpath%\migcab.sed
|
|
ECHO AppLaunched=%%AppLaunched%% 1>>%migpath%\migcab.sed
|
|
ECHO PostInstallCmd=%%PostInstallCmd%% 1>>%migpath%\migcab.sed
|
|
ECHO AdminQuietInstCmd=%%AdminQuietInstCmd%% 1>>%migpath%\migcab.sed
|
|
ECHO UserQuietInstCmd=%%UserQuietInstCmd%% 1>>%migpath%\migcab.sed
|
|
ECHO SourceFiles=SourceFiles 1>>%migpath%\migcab.sed
|
|
ECHO [Strings] 1>>%migpath%\migcab.sed
|
|
ECHO InstallPrompt= 1>>%migpath%\migcab.sed
|
|
ECHO DisplayLicense= 1>>%migpath%\migcab.sed
|
|
ECHO FinishMessage= 1>>%migpath%\migcab.sed
|
|
ECHO TargetName=BINARIES_DIR\migwiz.cab 1>>%migpath%\migcab.sed
|
|
ECHO FriendlyName=IExpress Wizard 1>>%migpath%\migcab.sed
|
|
ECHO AppLaunched= 1>>%migpath%\migcab.sed
|
|
ECHO PostInstallCmd= 1>>%migpath%\migcab.sed
|
|
ECHO AdminQuietInstCmd= 1>>%migpath%\migcab.sed
|
|
ECHO UserQuietInstCmd= 1>>%migpath%\migcab.sed
|
|
ECHO FILE0="usmtdef.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE1="guitrn.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE2="guitrn_a.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE3="iconlib.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE4="log.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE5="migapp.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE6="migism.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE7="migism.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE8="migism_a.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE9="migsys.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE10="miguser.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE11="migwiz.exe" 1>>%migpath%\migcab.sed
|
|
ECHO FILE12="migwiz.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE13="migwiz_a.exe" 1>>%migpath%\migcab.sed
|
|
ECHO FILE14="script.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE15="script_a.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE16="shfolder.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE17="sysfiles.inf" 1>>%migpath%\migcab.sed
|
|
ECHO FILE18="sysmod.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE19="sysmod_a.dll" 1>>%migpath%\migcab.sed
|
|
ECHO FILE20="migwiz.exe.manifest" 1>>%migpath%\migcab.sed
|
|
ECHO [SourceFiles] 1>>%migpath%\migcab.sed
|
|
ECHO SourceFiles0=BINARIES_DIR\ 1>>%migpath%\migcab.sed
|
|
ECHO [SourceFiles0] 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE0%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE1%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE2%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE3%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE4%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE5%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE6%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE7%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE8%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE9%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE10%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE11%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE12%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE13%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE14%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE15%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE16%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE17%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE18%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE19%%= 1>>%migpath%\migcab.sed
|
|
ECHO %%FILE20%%= 1>>%migpath%\migcab.sed
|
|
|
|
REM build migwiz.sed
|
|
ECHO [Version] 1>%migpath%\migwiz.sed
|
|
ECHO Class=IEXPRESS 1>>%migpath%\migwiz.sed
|
|
ECHO SEDVersion=3 1>>%migpath%\migwiz.sed
|
|
ECHO [Options] 1>>%migpath%\migwiz.sed
|
|
ECHO PackagePurpose=InstallApp 1>>%migpath%\migwiz.sed
|
|
ECHO ShowInstallProgramWindow=0 1>>%migpath%\migwiz.sed
|
|
ECHO HideExtractAnimation=1 1>>%migpath%\migwiz.sed
|
|
ECHO UseLongFileName=0 1>>%migpath%\migwiz.sed
|
|
ECHO InsideCompressed=0 1>>%migpath%\migwiz.sed
|
|
ECHO CAB_FixedSize=0 1>>%migpath%\migwiz.sed
|
|
ECHO CAB_ResvCodeSigning=0 1>>%migpath%\migwiz.sed
|
|
ECHO RebootMode=N 1>>%migpath%\migwiz.sed
|
|
ECHO InstallPrompt=%%InstallPrompt%% 1>>%migpath%\migwiz.sed
|
|
ECHO DisplayLicense=%%DisplayLicense%% 1>>%migpath%\migwiz.sed
|
|
ECHO FinishMessage=%%FinishMessage%% 1>>%migpath%\migwiz.sed
|
|
ECHO TargetName=%%TargetName%% 1>>%migpath%\migwiz.sed
|
|
ECHO FriendlyName=%%FriendlyName%% 1>>%migpath%\migwiz.sed
|
|
ECHO AppLaunched=%%AppLaunched%% 1>>%migpath%\migwiz.sed
|
|
ECHO PostInstallCmd=%%PostInstallCmd%% 1>>%migpath%\migwiz.sed
|
|
ECHO AdminQuietInstCmd=%%AdminQuietInstCmd%% 1>>%migpath%\migwiz.sed
|
|
ECHO UserQuietInstCmd=%%UserQuietInstCmd%% 1>>%migpath%\migwiz.sed
|
|
ECHO SourceFiles=SourceFiles 1>>%migpath%\migwiz.sed
|
|
ECHO [Strings] 1>>%migpath%\migwiz.sed
|
|
ECHO InstallPrompt= 1>>%migpath%\migwiz.sed
|
|
ECHO DisplayLicense= 1>>%migpath%\migwiz.sed
|
|
ECHO FinishMessage= 1>>%migpath%\migwiz.sed
|
|
ECHO TargetName=BINARIES_DIR\support\tools\fastwiz.EXE 1>>%migpath%\migwiz.sed
|
|
ECHO FriendlyName=Files and Settings Transfer Wizard 1>>%migpath%\migwiz.sed
|
|
ECHO AppLaunched=migload.exe 1>>%migpath%\migwiz.sed
|
|
ECHO PostInstallCmd="<None>" 1>>%migpath%\migwiz.sed
|
|
ECHO AdminQuietInstCmd= 1>>%migpath%\migwiz.sed
|
|
ECHO UserQuietInstCmd= 1>>%migpath%\migwiz.sed
|
|
ECHO FILE0="migload.exe" 1>>%migpath%\migwiz.sed
|
|
ECHO FILE1="migwiz.cab" 1>>%migpath%\migwiz.sed
|
|
ECHO [SourceFiles] 1>>%migpath%\migwiz.sed
|
|
ECHO SourceFiles0=BINARIES_DIR\ 1>>%migpath%\migwiz.sed
|
|
ECHO [SourceFiles0] 1>>%migpath%\migwiz.sed
|
|
ECHO %%FILE0%%= 1>>%migpath%\migwiz.sed
|
|
ECHO %%FILE1%%= 1>>%migpath%\migwiz.sed
|
|
|
|
set SEDPath=%migpath%
|
|
|
|
goto common
|
|
|
|
:end
|
|
if exist %_NTPostBld%\migwiz.exe.manifest del /f %_NTPostBld%\migwiz.exe.manifest
|
|
|
|
REM Delete the migpath directory if it's there. Also copy the fastwiz.exe to it's proper location
|
|
if defined migpath (
|
|
call ExecuteCmd.cmd "copy /Y %outpath%\fastwiz.exe %_NTPostBld%\support\tools\fastwiz.exe"
|
|
call ExecuteCmd.cmd "rd /s /q %migpath%"
|
|
)
|
|
|
|
seterror.exe "%errors%"& goto :EOF
|