dos_compilers/Logitech Modula-2 v1.1/PROGRAM.DEF

99 lines
3.0 KiB
Plaintext
Raw Permalink Normal View History

2024-07-01 00:43:04 +02:00
(* Version 1.10, Nov 1984 *)
DEFINITION MODULE Program;
(*
Sub-program loading and execution
Under MODULA-2/86, programs can be divided into
sub-programs (we call them 'programs') which are
loaded upon request.
These programs are executed like procedures:
- they have only one entry-point (body of
program's main module).
- after termination, their data do not exist any
longer. In the case of programs the code also
disappears and will be reloaded from disk upon
the next activation.
- programs may themselves activate other programs.
Derived from the Lilith Modula-2 system developed by the
group of Prof. N. Wirth at ETH Zurich, Switzerland.
*)
FROM System IMPORT Status;
EXPORT QUALIFIED
Call, GetErrorInfo;
PROCEDURE GetErrorInfo (VAR msg: ARRAY OF CHAR);
(*
- Obtain more information about a load error.
out: msg a string related to the last error.
After Call (below) has returned a Status value of
'modulenotfound' and 'incompatiblemodules', GetErrorInfo
will return the name of the offending module. (length is
up to 24 characters). It returns an empty string in all
other cases.
*)
PROCEDURE Call (programName: ARRAY OF CHAR;
shared: BOOLEAN;
VAR st: Status);
(*
- Load and execute a (sub) program.
in: programName file specification for the program,
shared whether to share resources,
out: st terminating status of the subprogram.
The file whose name is given in 'programName' is opened
loaded, and started. There is no default device or file
type; these must be supplied by the caller. The file must
contain a linked, relocatable Modula-2 program.
The load address is defined by the default allocation
schema, in which programs are loaded on top of stack and
a new stack is created for execution of the new program.
If 'shared' = TRUE then all sharable resources allocated
by the called program are owned by the calling program
(or possibly the caller of the caller...). Shared
resources are not released upon termination of the new
program.
Upon termination of the program, its memory is freed and
the old stack is established. All the resources used by
a terminating program are released, if they are not shared
and if they have not been released explicitly by the
program (files, heap, etc).
Any value of 'st' other than 'normal' indicates an
abnormal termination of the subprogram. In some cases
GetErrorInfo (above) will provide additional details.
Cautions:
In case of abnormal termination, Call does NOT print any
kind of error message.
Do not assign a procedure in the current program to a
procedure variable which could still exist after the
current program terminates (for example, a variable in a
shared resource or in the calling program). When the
current program terminates, all procedures in it must be
considered to cease to exist.
The loader in this module is not reentrant. This means
that interrupt processes must not load overlays!
*)
END Program.