(* Version 1.10, Nov 1984 *)
DEFINITION MODULE RS232Int;
(*
Interrupt-driven input/output via the RS-232
asynchronous serial port
Interrupts are treated with the standard procedure
IOTRANSFER. Charcters received are stored in a buffer of
400H characters.
This module initializes the serial port as follows:
baudRate = 1200, stopBits = 1,
parityBit = FALSE, evenParity = don't care,
nbrOfBits = 8
Derived from the Lilith Modula-2 system developed by the
group of Prof. N. Wirth at ETH Zurich, Switzerland.
*)
EXPORT QUALIFIED
Init, StartReading, StopReading,
BusyRead, Read, Write;
PROCEDURE Init (baudRate: CARDINAL;
stopBits: CARDINAL;
parityBit: BOOLEAN;
evenParity: BOOLEAN;
nbrOfBits: CARDINAL;
VAR result: BOOLEAN);
(*
- Initialize the serial port.
in: baudRate transmission speed,
stopBits number of stop bits (usually 1 or 2),
parityBit if TRUE, parity is used, otherwise not,
evenParity if parity is used, this indicates
even/odd,
nbrOfBits number of data bits (usually 7 or 8),
out: result TRUE if the initialization was completed.
The legal values for the parameters depend on the
implementation (e.g. the range of supported baud rates).
*)
PROCEDURE StartReading;
(*
- Allow characters to be received from the serial port.
This procedure initializes the communication controller to
generate interrupts upon reception of a character. It also
unmasks the corresponding interrupt level in the interrupt
controller.
*)
PROCEDURE StopReading;
(*
- Disable receiving from the serial port.
A call to this procedure disables the communication
controller from generating interrupts. In addition it
terminates the coroutine which listens to the line. The
old interrupt vector as well as the old state of the
interrupt controller (mask) is restored.
*)
PROCEDURE BusyRead (VAR ch: CHAR; VAR received: BOOLEAN);
(*
- Read a character from serial port, if one has been
received.
out: ch the character received, if any,
received TRUE if a character was received.
If no character has been received, then ch = 0C, and
received = FALSE.
*)
PROCEDURE Read (VAR ch: CHAR);
(*
- Read a character from the serial port.
out: ch the character received.
As opposed to BusyRead, Read waits for a character to
arrive.
*)
PROCEDURE Write (ch: CHAR);
(*
- Write a character to the serial port.
in: ch character to send.
Note: no interpretation of characters is made.
*)
END RS232Int.