TURBO PASCAL 5.0: ANSWERS TO COMMON QUESTIONS
|
||
---------------------------------------------
|
||
|
||
1. Can I build programs bigger than 64K?
|
||
|
||
The total size of a program's code is only limited by the
|
||
memory you have available; but each unit (module) can be
|
||
no larger than 64K, since it has to have its own code
|
||
segment.
|
||
|
||
The data segment is still no more than 64K, but the heap
|
||
is unlimited just as in 3.0. In fact, we've rewritten the
|
||
heap manager to make it much more efficient. There's no
|
||
waste when allocating memory (in 3.0, all blocks were
|
||
rounded up to a factor of 8), and you can install a heap
|
||
error routine that gets called if an allocation request
|
||
fails. All in all, 5.0's heap manager is much faster than
|
||
version 3.0.
|
||
|
||
2. Can Turbo Pascal run on generic MS-DOS machines?
|
||
|
||
TPC.EXE will run on generic machines when you use the /Q
|
||
option. The System, Overlay, Dos, and Printer standard
|
||
units will operate correctly on MS-DOS generic machines.
|
||
Generated .EXE's are MS-DOS compatible as long as you
|
||
don't use the special PC units (such as Crt, Graph, and
|
||
Graph3).
|
||
|
||
3. Does Turbo Pascal 5.0 support large integers?
|
||
|
||
Yes, TP 5.0 has virtually every incarnation of 8-, 16-, and
|
||
32-bit integers: shortint, integer, longint, byte, and
|
||
word.
|
||
|
||
4. Will the toolboxes for 4.0 work with 5.0?
|
||
|
||
Yes, all 4.0 versions of the toolboxes will work with
|
||
Turbo Pascal 5.0. In a few cases, minor changes to
|
||
compiler directives are recommended. Refer to the Turbo
|
||
Pascal README file for more information.
|
||
|
||
5. Does Turbo Pascal version 5.0 support conditional
|
||
compilation?
|
||
|
||
Yes, Turbo 5.0 includes conditional compilation support.
|
||
You use {$DEFINE ...} and {$UNDEF ...} for symbols and
|
||
{$IFDEF ...}. Using the {$IFOPT ...} conditional
|
||
directive, you can even test the settings of compiler
|
||
directives like R-, N+, and others. For the command-line
|
||
compiler, you can define symbols with the /D directive. In
|
||
the integrated compiler, you can also define symbols via
|
||
the Options/Compiler/Conditional Defines menu command.
|
||
|
||
6. How much of the 64K in the data segment is actually
|
||
available to my program?
|
||
|
||
The amount of data segment used by the run-time library
|
||
depends on which standard units you use in your program.
|
||
Here is the data segment usage (in bytes) for each unit:
|
||
|
||
UNIT Data Size
|
||
---- ---------
|
||
System 664
|
||
Overlay 10
|
||
Crt 20
|
||
Dos 6
|
||
Printer 256
|
||
Graph 1070
|
||
Turbo3 256
|
||
Graph3 0
|
||
=========
|
||
2282
|
||
|
||
The total size of the data segment is 65,520 bytes. If you
|
||
used only the System unit, the amount of data segment
|
||
space left over would be
|
||
|
||
65520 - 664 = 64856 bytes
|
||
|
||
7. What is the largest global data structure you can
|
||
allocate?
|
||
|
||
The maximum size of a single variable that can be
|
||
allocated on the heap is 65,521 bytes.
|
||
|
||
8. How do I find out how much code and data were generated by
|
||
the compiler for a program or unit?
|
||
|
||
If you are using the integrated environment, build your
|
||
program or unit and then use the Get Info command in the
|
||
Compile menu. This will bring up a window of information
|
||
that includes the size of code and data.
|
||
|
||
If you are using the command-line compiler, the size of
|
||
generated code and data is displayed on the screen at the
|
||
end of compilation.
|
||
|
||
9. Are the .OBJ files generated by Turbo C and Turbo
|
||
Assembler compatible with 5.0?
|
||
|
||
You can write Turbo C or Turbo Assembler routines and link
|
||
the .OBJ files into your Turbo Pascal programs by using
|
||
{$L} compiler directives. Turbo Pascal 5.0 generates .TPU
|
||
(Turbo Pascal Unit) files, not .OBJ files. We've made that
|
||
decision for many reasons:
|
||
|
||
A. TP 5.0's .TPU files are smaller than .OBJ's, and they
|
||
contain symbolic information important to the support
|
||
of Pascal's strict type conventions (types, constants,
|
||
etc.).
|
||
|
||
B. .TPU files allow "smart linking" - elimination of
|
||
unused code and data on a procedure-by-procedure
|
||
basis.
|
||
|
||
C. .TPU's allow built-in project management through
|
||
version 5.0's Make and Build commands.
|
||
|
||
D. .TPU's allow faster compilation speeds (34,000 lines
|
||
per minute on a PS/2 Model 60).
|
||
|
||
10. Will the $L compiler directive work for compiler object files
|
||
other than assembler?
|
||
|
||
That depends on the language. TURBO requires all the code
|
||
in the .OBJ to be in *one* CODE segment, and all the data
|
||
to be in *one* DATA segment. With assembly language that's
|
||
easy, but it may not work with some high-level language
|
||
compilers. You can use Turbo C to generate .OBJ files for
|
||
use by Turbo Pascal programs. An example, CPASDEMO.PAS is
|
||
included on the distribution disks.
|
||
|
||
11. Does the built-in linker eliminate unused data?
|
||
|
||
Yes. Unused code AND data are stripped when you compile to
|
||
disk.
|
||
|
||
12. If two units use a third unit, does the third unit get
|
||
included twice in my program?
|
||
|
||
No. All your units are "linked" together when you compile
|
||
your program. Only one copy of each procedure and function
|
||
used is generated. There is NO duplication of run-time
|
||
code. In fact, Turbo Pascal 5.0 has "smart linking," which
|
||
eliminates any unused code and data from the final .EXE.
|
||
|
||
13. What happens if you attempt to link another unit in which the
|
||
compiler directives are set differently?
|
||
|
||
Compiler directives are local to the unit they are
|
||
declared in. Thus, the compiler directives in one unit, or
|
||
in the main program, have no effect on the directives set
|
||
in another unit.
|
||
|
||
14. Can I create my own .TPL file?
|
||
|
||
Yes, but Turbo Pascal will only use the TURBO.TPL library
|
||
file. If you want to add your own units to the TURBO.TPL
|
||
file, you can use the unit mover program (TPUMOVER.EXE).
|
||
For example, you might want a customized version of
|
||
TURBO.TPL for each of the programs you're developing. A
|
||
corresponding configuration file for Turbo Pascal would
|
||
specify a different Turbo directory and thus fetch the
|
||
appropriate .TPL file for each of your projects.
|
||
|
||
15. What rules should I follow when writing an interrupt
|
||
handler?
|
||
|
||
The following is a list of rules to keep in mind when
|
||
writing an interrupt handler:
|
||
|
||
A. Use GetIntVec and SetIntVec to install/uninstall
|
||
interrupt handlers
|
||
|
||
B. Use the interrupt directive
|
||
|
||
C. Be careful about reentrancy. Don't use any calls to
|
||
DOS or to Turbo Pascal's overlay or heap management
|
||
routines in your interrupt handler
|
||
|
||
D. Interrupt procedures and functions must use the far
|
||
call model (use the {$F+} option)
|
||
|
||
E. Be proficient with the BIOS and assembly language
|
||
before attempting to write an interrupt handler
|
||
|
||
F. Make sure your interrupt handler is not in an
|
||
overlaid unit.
|
||
|
||
16. Does a procedure or function in a program have to be of a
|
||
near or far call model?
|
||
|
||
If you are using overlays or procedural variables, you
|
||
should probably turn {$F+} on for all units and the main
|
||
program (the extra overhead of always using far calls is
|
||
usually quite small).
|
||
|
||
Otherwise, Turbo Pascal automatically selects the correct
|
||
call model. A routine is always a near call model unless
|
||
|
||
1) it is declared in the interface section of a unit
|
||
|
||
2) you override the default call model by using the {$F+}
|
||
compiler option
|
||
|
||
You should also use the {$F+} option to override the
|
||
default call model if you are writing interrupt handlers,
|
||
error handlers, or exit procedures.
|
||
|
||
17. How do I write reentrant code in Turbo Pascal?
|
||
|
||
If a routine follows these rules, it is reentrant:
|
||
|
||
A. All data is allocated on the stack.
|
||
|
||
B. The routine doesn't use any global variables.
|
||
|
||
C. The routine can be interrupted at any time without
|
||
affecting the execution of the routine.
|
||
|
||
D. The routine doesn't call any other routines that are
|
||
not reentrant (e.g., DOS I/O).
|
||
|
||
18. What is the best approach to taking advantage of the new IEEE
|
||
floating-point types?
|
||
|
||
The new IEEE floating-point types are available when you
|
||
compile your program with {$N+} and you have a math
|
||
coprocessor; they are also available if you don't have a
|
||
coprocessor, but specify {N+,E+}. The 8087 emulator has
|
||
greater precision, but is significantly slower than the
|
||
fast, 6-byte, software-only reals. When developing
|
||
programs that will be compiled and run on machines without
|
||
the 8087 coprocessor, consider the trade-offs of speed
|
||
(built-in reals) vs. precision (8087 hardware/emulation)
|
||
and make the appropriate choice.
|
||
|
||
19. What type is Comp? What is it useful for?
|
||
|
||
The Comp type is a cross between an integer and a real
|
||
type and is available when 8087 code is generated {$N+}.
|
||
If no math coprocessor is available, specify {$N+,E+} and
|
||
the emulator will support the Comp type.
|
||
|
||
The compiler treats it as a real type without an exponent.
|
||
Thus Comp is useful when you need to store extremely large
|
||
numbers but don't need a decimal point. For example, you
|
||
might use variables of type Comp to store amounts in cents
|
||
and divide the value of the variable by 100 to determine
|
||
what the value in dollars and cents would be.
|
||
|
||
20. How many significant digits do the 8087 floating-point types
|
||
provide?
|
||
|
||
Type Digits of precision
|
||
-------- -------------------
|
||
single 7-8
|
||
double 15-16
|
||
extended 19-20
|
||
comp 19-20
|
||
|
||
21. Are the intermediate results of real number expressions
|
||
stored in the 8087 registers?
|
||
|
||
No. The user (8086) stack is used to store intermediate
|
||
results of real number expressions.
|
||
|
||
22. How does rounding work with IEEE floating point?
|
||
|
||
The 8087 math coprocessor uses a different method for
|
||
rounding numbers than what you may be used to. In order to
|
||
achieve a more even distribution of values, the 8087 uses
|
||
a method sometimes called "Banker's Rounding." This method
|
||
dictates that a number will always be rounded to the
|
||
nearest EVEN number. Note that this is quite different
|
||
than always rounding UP. Here are a couple of examples:
|
||
|
||
Round(0.5) = 0
|
||
Round(1.5) = 2
|
||
|
||
23. How do you do I/O redirection?
|
||
|
||
If you want to do DOS I/O redirection when running an .EXE
|
||
file generated by Turbo Pascal, DON'T use the Crt unit.
|
||
If you do, make sure you assign a text file variable to
|
||
the standard DOS output device.
|
||
|
||
Assign(Output,''); { assign a text file variable }
|
||
{ to a null file name }
|
||
ReWrite(Output); { do a rewrite here }
|
||
|
||
Any Write statement that does not specify a file variable
|
||
will be redirected to the DOS standard output file. You
|
||
can also Write(Output,...).
|
||
|
||
24. How do you go about upgrading version 3.0 programs with
|
||
lots of chain files?
|
||
|
||
Chaining is not possible with .EXE files. Control can be
|
||
passed to another program by use of the EXEC procedure in
|
||
the DOS unit. You can also use 5.0's overlay manager to
|
||
build very large programs.
|
||
|
||
25. Are overlays supported in 5.0?
|
||
|
||
Yes! See the example program OVRDEMO.PAS and refer to the
|
||
Turbo Pascal manual for information on overlays.
|
||
|
||
26. Is there any support in Turbo Pascal 5.0 for file and record
|
||
locking?
|
||
|
||
There's a standard variable in the System unit called
|
||
FileMode, which you can use to assign an open mode for use
|
||
in all subsequent Resets. There are no record-locking
|
||
routines implemented in the standard version, but they are
|
||
easily implemented through MsDos calls.
|
||
|
||
27. Does Turbo 5.0 support procedure parameters?
|
||
|
||
Yes. See PROCVAR.PAS, DIRDEMO.PAS, and refer to the
|
||
Reference Guide for a complete description.
|
||
|
||
28. Can you use identifiers other than scalar in the case statement?
|
||
|
||
As with Turbo Pascal 3.0 and 4.0, case statements allow
|
||
the following ordinal types: Char, Boolean, Integer, and
|
||
user-defined enumeration.
|
||
|
||
29. Is the run-time license policy the same as in version 3.0?
|
||
|
||
YES, there are no royalties!
|
||
|
||
30. What about a debugger, who has one for 5.0?
|
||
|
||
There is a built-in debugger in version 5.0. In addition,
|
||
you can use the Turbo Debugger on .EXE files generated by
|
||
Turbo Pascal 5.0. Finally, you can use any debugger that
|
||
can process .MAP files (see the Options/Linker menu).
|
||
|
||
31. C has static variables, is there anything similar in 5.0?
|
||
|
||
You can declare private global variables in the
|
||
implementation part of a unit. Such variables are only
|
||
visible within that unit. Like other globals, they retain
|
||
their values across calls.
|
||
|
||
Typed constant declarations declared within a procedure or
|
||
function also behave exactly like C's static variables.
|
||
They are local in scope but since they are allocated in
|
||
the data segment, they retain their values from call to
|
||
call.
|
||
|
||
32. What Turbo Pascal 3.0 code will cause the most problems
|
||
converting to version 5.0?
|
||
|
||
With our UPGRADE program (see appropriate Appendix in your
|
||
manual), it's not very difficult to port your code to 5.0.
|
||
It depends a lot on the type of programs you write.
|
||
|
||
The passing of parameters on the stack is done much more
|
||
efficiently now, so changes will have to be made to inline
|
||
machine code and assembly language. Most of the changes
|
||
are optional: using new types, breaking your program into
|
||
modules to take advantage of separate compilation. (The
|
||
UPGRADE program has a special option to help you "unitize"
|
||
your program too. It does all the "typing" for you.)
|
||
|
||
Some stricter type-checking is performed in version 5.0.
|
||
For example, the Dos unit now defines the often-seen
|
||
registers record type (AX, BX...); MsDos and Intr now take
|
||
this type. In this case, you can type-cast or change the
|
||
type identifier and recompile.
|
||
|
||
33. How do I use .BIN files provided by third-party vendors with
|
||
5.0?
|
||
|
||
We've included a utility on your distribution disk called
|
||
BINOBJ.EXE, which converts binary files into .OBJ files
|
||
that are linkable to your Turbo Pascal 5.0 programs. In
|
||
general this will only work if the binary files contain
|
||
data, not code. Contact your third-party vendor to see if
|
||
they also provide .OBJ versions of their programs.
|
||
|
||
34. Why does TURBO sometimes try to read from another drive
|
||
when I run it?
|
||
|
||
When you leave Turbo Pascal, it saves the name and path of
|
||
the file you were last editing in a pick list. The next
|
||
time you load Turbo, it checks this pick list and tries to
|
||
load the file you were last editing. If the file you were
|
||
last editing was in another drive, Turbo will try to read
|
||
from that drive. This also occurs if you have installed
|
||
another drive as your Turbo Directory.
|
||
|
||
35. Does Turbo Pascal 5.0 support EMS?
|
||
|
||
Yes, Turbo Pascal 5.0 will use up to 64K of EMS for
|
||
storing the edit buffer. In addition, you can instruct the
|
||
Overlay unit to place your overlaid units on EMS. Finally,
|
||
EMS.PAS on the distribution disk shows you how to access
|
||
EMS memory.
|
||
|
||
36. How can I allocate my own I/O buffer for a text file?
|
||
|
||
You can use the procedure SetTextBuf to allocate your own
|
||
text file buffer either in the data segment or on the
|
||
heap.
|
||
|
||
37. Why aren't the new settings used after I install TURBO.EXE
|
||
using the TINST.EXE program?
|
||
|
||
You probably have a .TP file in the current or Turbo
|
||
directory being loaded and the settings in the .TP file
|
||
override the settings installed by TINST. Delete the .TP
|
||
file.
|
||
|
||
38. Is the string size limit still 255 characters?
|
||
|
||
Yes, it's just like in 3.0; you can write your own
|
||
routines to handle greater than 255 character strings.
|
||
|
||
39. Can I still write to file 'Con' without changes?
|
||
|
||
The 'Con' file is gone, but you can still write to the
|
||
screen with a simple Write with no file variable. The file
|
||
system has been completely redesigned to allow you to
|
||
write your own text file device drivers. With these, you can
|
||
implement a Pascal-like text-file interface to any device,
|
||
such as serial ports, windowing systems, memory, etc.
|
||
|
||
40. What is constant merging?
|
||
|
||
For example, when you use the same string constant more
|
||
than once in a program block, the compiler only saves one
|
||
copy of this string. In the generated program, a pointer
|
||
is created that references the one copy of this string in
|
||
the generated .EXE file.
|
||
|
||
41. Have Turbo Pascal 3.0 run-time error codes changed in
|
||
Turbo Pascal 5.0?
|
||
|
||
Yes, error codes have changed; refer to Appendix I in the
|
||
Reference Guide. The Turbo3 unit contains a version 3.0
|
||
compatible IOResult function.
|
||
|
||
42. What books can I read that will help me with Turbo Pascal
|
||
5.0?
|
||
|
||
The Turbo Pascal Tutor is an excellent reference to Turbo
|
||
Pascal. Also, Osborne/McGraw Hill has a line of books
|
||
about Borland's products.
|
||
|