dos_compilers/Microsoft Cobol v5/DOCS/README.DOC
2024-06-30 15:35:16 -07:00

540 lines
18 KiB
Plaintext

README.DOC
Microsoft(R) COBOL, Version 5.0
(C) Copyright Microsoft Corporation, 1993
This document contains essential information for version 5.0
of the Microsoft COBOL Professional Development System for
MS-DOS(R) and Microsoft(R) Windows. The information in this
document is more up-to-date than the printed documentation.
See the DOCUPDT.DOC file for information on printed documentation
corrections (located in the \COBOL\DOCS sub-directory).
========================< CONTENTS >=================================
This file contains information on product usage and
restrictions organized as follows:
NEW FEATURES
INSTALLATION
PROGRAMMER'S WORKBENCH
COMPILER AND LINKER
ANIMATOR
CODEVIEW
SAMPLE PROGRAMS
MISCELLANEOUS
===================================================================
NEW FEATURES
============
Improved Support for Microsoft Windows 3.x
-------------------------------------------
o Shared run-time system (COBLIB) is now supported under
Windows 3.x. The run-time system is provided as COBLIB.DLW.
o Because the COBOL compiler uses COBLIB itself, this means
that the compiler, Animator, etc., will be able to run as
Windows applications, making use of extended memory.
o QuickWin support is now provided in a DLL. This means that
dynamically called sub-programs can now make use of all
COBOL screen handling techniques.
o COBOL 5.0 provides support for interoperability with
Microsoft Visual Basic 2.0 for Windows. You can write
Visual Basic Graphical User Interfaces and call COBOL DLL's.
For additional information, see the COBOL Programming for
Windows book, Chapter 4 "Building Visual Basic
Applications."
Animator Improvements
---------------------
o Ability to monitor many data items. Each item is displayed
in its own window on the screen.
o The "Watch" statement. This effectively performs a Step command,
but also displays the contents of all data items used in the
COBOL statement before and after execution of the Step. This saves
the user from having to manually query the data items used in the
statement.
o Set a breakpoint on a data-item, so that if the contents of the
data-item changes, execution of the program will stop on the
statement that changes the data-item.
o Set a breakpoint on a COBOL statement and specify several lines
of code to be executed when the breakpoint is encountered (allows
temporary patching of the code - the source file is not changed).
o A "base" Animator is also provided for low memory situations
(ANIMBASE.EXE).
PANELS Character Window Tool
----------------------------
PANELS allows applications to create multiple windows on
character mode screens. Support is also provided to allow
ACCEPT/DISPLAY statements to be sent to the different Windows.
This allows easier development of pull-down menus, pop-up
windows, etc. on character mode screens.
Extfh/BTrieve Interface
-----------------------
New modules are being provided to allow programs that use standard
COBOL file handling syntax to access BTrieve files. Another module
is provided to allow programs that make calls to BTrieve to access
indexed-sequential files created using the standard COBOL file
handler (EXTFH).
COBOL Syntax Enhancements
-------------------------
There have been various COBOL syntax enhancements, mostly based
on the CODASYL Journal of Development, including:
o EVALUATE statement extended
o PERFORM UNTIL EXIT
o SET condition-name TO FALSE
o READ WITH WAIT
o READ WITH IGNORE LOCK
o ACCEPT/DISPLAY WITH UPPER/LOWER
o "C" and "R" accepted as currency signs
o VALUE clause extended to include "LENGTH OF identifier",
o "ADDRESS OF identifier" and AND'ing and OR'ing of numbers
(used for programming for GUI environments).
Mainframe Compatibility Enhancements
------------------------------------
o Support for the DOS/VS COBOL dialect.
o Mainframe compatible arithmetic. A new directive has been added
to provide mainframe compatible results in arithmetic statements.
The difference is in the way intermediate results are stored
during arithmetic statements.
o Mainframe file status codes are now supported.
o Obtain record length information for FILE SECTION records via
negative subscripting (a common mainframe technique).
o Improved support for OSVS perform behavior.
Western National Language Standards Supported
---------------------------------------------
The "NLS" compiler directive has been provided to indicate that a
program should use a specified language/territory/codepage. The
program then uses the appropriate characters and collating sequences
for currency signs, decimal and thousands separator and comparisons.
Performance Improvements
------------------------
There have been improvements in the speed and size of the code
output by the compiler. The main performance improvements
come from the following:
o Better use of 80x86 registers, leading to a general
20% improvement in computational operations.
o Speed of access to linkage section has been doubled
in programs with greater than 64K of data.
o Improvement in CALL performance.
o 40% speed improvement in accessing tables greater than 64K.
o Improvement in SEARCH performance.
o Improvements in file-handling performance.
o Use of the XM DOS Extender can improve performance of
larger programs.
Other Enhancements
------------------
o The compiler can now output assembler listings in a form that
can be input to MASM if required.
o Environment variables can be set up in a text file, therefore
reducing the amount of DOS environment space that is needed.
The variables can be read and written by COBOL programs.
New Call-by-Name Routines
-------------------------
o CBL_EXIT_PROC
o CBL_SUBSYSTEM
o CBL_COPY_FILE
o CBL_GET_SCR_LINE_DRAW
o CBL_GET_OS_INFO
o PC_FIND_DRIVES
XM DOS Extender
------------
o Enable your applications to exceed the 640K DOS memory limit.
o Enables up to 16MB of extended memory to be made available to
your application.
o Supports VCPI, DPMI and XMS protocols.
o No need to modify your programs, simply recompile and relink.
Updated Windows 3.1 components
------------------------------
o Image Editor:
With Image Editor (IMAGEDIT.EXE), you can create graphical
images to represent files, windows, cursors, and other
objects in your Windows applications.
o Dialog Editor:
With Dialog Editor (DLGEDIT.EXE), you can visually design and
test a dialog box on your screen instead of programmatically
using DIALOG statements in your resource-definition file.
o Font Editor:
With Font Editor (FONTEDIT.EXE), you can modify existing
fonts to create new fonts for your applications.
o Resource Compiler:
With Resource Compiler (RC.EXE) you can compile your Windows
resource files and resource-definition files for inclusion
in Windows .EXE's and .DLL's.
Codeview 4.05 Debugger
----------------------
Supports debugging of mixed language DOS applications including
Cobol, C, and MASM.
===================================================================
INSTALLATION
============
Installing HIMEM.SYS
--------------------
For best results, LINK requires HIMEM.SYS (which is supplied
with COBOL 5.0 but not installed by Setup). If HIMEM.SYS
(or some other memory manager) is not already installed on
your computer, follow these instructions:
1. Verify that HIMEM.SYS is located in the \COBOL\BIN
directory and that \COBOL\BIN is included in the
PATH statement in your AUTOEXEC.BAT file.
2. Add this statement to your CONFIG.SYS file:
DEVICE = C:\COBOL\BIN\HIMEM.SYS
The DEVICE command for HIMEM.SYS enables the use of
extended memory. Therefore, this command must appear
in your CONFIG.SYS file before any commands that
start device drivers, or programs that use extended
memory such as EMM386.EXE.
Path Length
-----------
For best results, install the default \COBOL directories.
If you choose other installation directory paths, choose
paths of reasonable length. Some directory paths are added
to the PATH statement in your AUTOEXEC.BAT, which is limited
to 128 characters.
Path Statement Characters
-------------------------
Do not use invalid path characters, such as:
< > * " '
in the Setup utility.
Source and Target Drive Specification
-------------------------------------
Do not specify invalid drives when prompted for the
installation source drive or destination drive in the
Setup utility.
Using NEW-VARS.BAT
------------------
After the initial installation of COBOL 5.0, any subsequent
installations will create a new NEW-VARS.BAT. This may
delete needed statements from the original file. If you
re-install COBOL 5.0, make a backup of NEW-VARS.BAT to
merge with the new file.
===================================================================
PROGRAMMER'S WORKBENCH
======================
Segmented Programs
------------------
Segmented COBOL programs cannot be run from PWB.
Using Library Routines (call-by-name) for Mouse
-----------------------------------------------
Do NOT use the mouse support Library Routine CBL_TERM_MOUSE
under PWB for builds using Shared Runtime System (this call
is handled by the runtime system). Use of this call under PWB
may cause your system to hang.
Windows .DLL Projects
---------------------
If you debug a Windows .DLL project, to change from the
debug build options to the release build options, do the
following:
1. Close the debug project you are working on.
2. Choose "Use Release Option" from the Build Options dialog
box.
3. Create a new project (.MAK file) for the Windows .DLL
using the release options.
===================================================================
COMPILER AND LINKER
===================
ANSI Standard for String Literals
---------------------------------
The ANSI Standard for string literals rule is enforced
in COBOL version 5.0. COBOL versions 4.5 and earlier
did not enforce this rule. For this reason, programs
compiled with earlier versions of COBOL that do not
conform to this rule may produce a syntax error.
For more information and the exact wording of this
ANSI rule, see the "Continuation of Lines" section in
the COBOL Language Reference book Chapter 2, page 77.
By-Value Parameter Passing in CALL Statements
---------------------------------------------
Dynamically linked COBOL programs cannot pass parameters by
value, only by reference. Statically linked COBOL
Programs can pass parameters either way.
Sequential File Data Compression
--------------------------------
To compress data in a sequential file, you must compile
using the CALLFH directive.
Using WINDOWS.78 in a COBOL Program
-----------------------------------
When WINDOWS.78 is used in a COBOL program, the directive
REMOVE(IGNORE) must be used to avoid a compiler error.
For an example of how to use the REMOVE(IGNORE) directive,
refer to SYSMETS.CBL--a sample program located in the
\COBOL\SAMPLES\WINDOWS directory.
===================================================================
ANIMATOR
========
Animating Sub-Programs
-------------------------
To animate a program which is called by another program,
you must compile using the PARAMCOUNTCHECK directive.
For more information, Refer to System Reference,
Appendix D (Directives of Compiler), page 578.
Using Animator From PWB
-----------------------
If you receive a 198 error while animating under PWB, this is probably
caused by insufficient system memory needed to load your program and
Animator. The best solution to this is to ensure Animator has access to
extended memory by checking the "USE XM for COMPILE and ANIMATE"
check box on the COBOL Compiler options screen in PWB.
The program can also be animated from the command line.
In a very large program, or when using certain animator
functions, ANIMBASE may have to be used in place of ANIMATOR.
Using the Cobol Compiler Icon with the ANIM directive
-----------------------------------------------------
1. Click on the Cobol Compiler icon
2. Type the filename and ANIM directive as you would
at the command line. When the compile finishes
successfully, LINK is executed automatically.
3. Make LINK the active window to allow LINK to process.
4. Select the OK button from the Application Terminated
dialog box.
===================================================================
CODEVIEW
========
Arithmetic Data Types
---------------------
Comp-1, Comp-2, and External Floating Point Data Items are
not supported.
Array Subscripts
----------------
Index names are not supported as subscripts.
Conditional Breakpoints
-----------------------
When a breakpoint expression is entered that contains
blanks, the expression must be quoted or parenthesized.
For instance, to use
a + 1
as a breakpoint expression, enter
bp ?(a + 1)
or
bp ?"a + 1"
The BP= Command (Break on change) will only accept
single data items, such as:
bp= b(1)
bp= x
Multiple-term expressions are not allowed. For example:
bp= (a + b)
bp= (a + 1)
bp= (a * 5 + x(2))
Indexed data items are allowed, but only if the index
is a literal:
bp= q(5)
bp= a(1)
CVPACK Configuration
--------------------
Codeview uses CVPACK.EXE. There are two possible versions of
CVPACK which can be installed for use with COBOL 5.0:
CVPACKX.@XE and CVPACK.@XE.
CVPACKX.@XE takes advantage of extended memory. CVPACK.@XE is
strictly for Real Mode use when an extended memory manager
is NOT present. One of these files will be installed as CVPACK.EXE,
depending upon installation options that you choose.
During Setup, on the CVPACK Configuration screen, if you
choose "yes" to use the extended version of CVPACK, CVPACKX.@XE
is installed as CVPACK.EXE, and CVPACK.@XE is installed as
CVPACKR.EXE. If you choose "no", CVPACK.@XE is installed as
CVPACK.EXE, and CVPACKX.@XE is installed as CVPACKX.EXE.
Double-Quoted Integers
----------------------
Double-quoted integers used in relational operations,
such as:
"5" = 5
are not recognized.
Numeric Literals
----------------
Leading zeroes are required in decimals. For instance, 0.01
is accepted as a valid numeric literal; .01 is not.
Radix Settings
--------------
If n16 is set, and a data item consists completely of
hex digits, the item will not be read as a symbol, but
as a hex number. For instance, the conditional breakpoint
bp ?a
will treat "a" as the number 10.
Registers Window Flag
---------------------
PL and NC flags are not supported in the registers window.
Reserved Words
--------------
The following are CodeView reserved words, and may not be
used as identifiers anywhere in programs which are to be
debugged:
main
winmain
entgqq
_main
===================================================================
SAMPLE PROGRAMS
===============
MOUSMENU.CBL Program
--------------------
The sample file C:\cobol\samples\mousmenu.cbl should be run
in a full-screen DOS box in Windows. The mouse will not
function correctly in a windowed DOS box.
====================================================================
MISCELLANEOUS
=============
386 Minimum Requirement
-----------------------
An 80386 or higher processor is recommended for the
following utilities:
PWB Microsoft Programmer's WorkBench
CV Microsoft CodeView
LINK Microsoft Segmented Executable Linker
EXEHDR Microsoft EXE File Header Utility
IMPLIB Microsoft Import Library Manager
LIB Microsoft Library Manager
NMAKE Microsoft Program Maintenance Utility
HELPMAKE Microsoft Help File Maintenance Utility
BSCMAKE Microsoft Browser Database Maintenance Utility
SBRPACK Microsoft Browse Information Compactor
CVPACK Microsoft Debugging Information Compactor
RM Microsoft File Removal Utility
UNDEL Microsoft File Undelete Utility
EXP Microsoft File Expunge Utility
WX/WXSRVR Microsoft WX/WXServer Utility
BTrieve
-------
When using BTrieve to access information on a server,
if the current working drive is not mapped to the server
that you are using, the file specification must include
the server path (drive letter).
For example: If the current working drive is C and the
server drive is F, then the "select" statement on page
133 of the System Reference would look like this:
select testfile-1 assign to "f:\test-1.dat"
Conversion Utilities
--------------------
TABX, Convert3, and Convert5 are to be used only to
convert files from another dialect, and will not
run if EMM386 is installed.
H2CPY
-----
Do not use H2CPY on WINDOWS.H. The WINDOWS.78 and
WINDOWS.CPY files are provided in \cobol\samples\windows as correct
conversions of WINDOWS.H.
Microsoft C 7.0
---------------
Mixed-Language programming using Microsoft C/C++ 7.0 and
COBOL 5.0 is possible. However, floating point data types
can only be used in one or the other language; not both.
This restriction avoids link errors caused by conflicts in
the C and COBOL floating point support libraries.
User-Created Libraries
----------------------
Libraries created using LIB.EXE cannot be used in the
"lib" field of a LINK command unless the calling programs
were compiled with the LITLINK compiler directive.
If LITLINK is not used, the user-created libraries should
be placed in the .OBJ field of the LINK command in order
to be linked statically.